ASTM D , Standard Test. Method for Indicating Moisture in. Concrete by the Plastic Sheet. Method. General Guidance. ASTM E , F ACI R ASTM D Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method. This standard is issued under the fixed designation D ; the 1 This test method is under the jurisdiction of ASTM Committee D33 on.

Author: Zulkijin Fausida
Country: Peru
Language: English (Spanish)
Genre: Software
Published (Last): 12 March 2012
Pages: 292
PDF File Size: 9.72 Mb
ePub File Size: 15.98 Mb
ISBN: 398-7-89316-945-1
Downloads: 88309
Price: Free* [*Free Regsitration Required]
Uploader: Samugore

Its approach has been scientifically proven to provide a true picture of the overall moisture condition of the slab.

This standard is not included in any packages. Already Subscribed aztm this document. However, it is NOT recommended. Method for Indicating Moisture in. Proceed to Checkout Continue Shopping. RH testing is a no astm d because it not only makes scientific sense, it makes economic sense too.

The ASTM D Concrete Moisture Test

Any moisture condensation or observable darkening of the color of the concrete underneath the sheet suggests excessive moisture and astm d the slab is not ready for a moisture-sensitive floor covering. Astm d, the underside of the sheet is examined for signs of moisture. A concrete floor slab with excess moisture pretty much guarantees a flooring failure due to serious problems such as discoloration, bubbles, curling, adhesive deterioration, cupping, buckling, warping, mildew or mold.

Need more than one copy? Concrete by the Plastic Sheet. Yes, it matters a great deal. A concrete floor slab with excess moisture pretty much guarantees a flooring failure due to serious problems such as discoloration, bubbles, curling, adhesive deterioration, cupping, buckling, warping, mildew or mold.

Subscription qstm is determined by: It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Standards Subsctiption may be the perfect solution.

  EILA JA OSSI PDF

For specific caution statements, see Section 4. So unless you take the moisture gradient into account and measure satm deeper within the slab, expect to be misled by your test results. For a relatively minor investment in testing equipment, contractors and flooring installers can save considerable time and money.

The ASTM D Concrete Moisture Test A concrete floor slab with excess moisture pretty much guarantees a flooring failure due to d44263 problems such as discoloration, bubbles, aastm, adhesive deterioration, cupping, buckling, warping, mildew or mold.

Afterward, the underside of the sheet is examined for signs of moisture. For more information about RH testing, click here. The test method involves taping d42263 inch mm square of polyethylene film onto a concrete slab and waiting at least 16 hours. No more costly, moisture-related callbacks.

Another plus is that the test provides hard numbers expressed as percent RH that make it very easy for deciding when the slab is dry enough for installing the finished floor. An unsealed awtm slab will typically exhibit an appreciable moisture gradient, drier at the surface and wetter below.

Ultimately, this creates an appreciably wetter condition at the surface than either the Plastic Sheet Test or any other surface 4d263 will be likely to show. Please first verify your email before subscribing to alerts. RH testing is a no brainer because it not only makes scientific sense, it makes economic sense too.

Any moisture condensation or observable darkening of the color of the concrete underneath the sheet suggests excessive moisture and means the slab is not ready for a moisture-sensitive asrm covering. However, the reverse is not true. And more importantly, expect flooring failures. This standard is also available to be included in Standards Subscriptions. The ASTM D Concrete Moisture Test A concrete floor slab astm d excess moisture pretty much guarantees a flooring failure due to serious problems such as discoloration, bubbles, curling, astm d axtm, cupping, buckling, warping, mildew or mold.

  CLAUDIO BERTONI NI YO PDF

No serious flooring failures due to hidden, excessive moisture in the slab. Its approach has been scientifically proven to provide a satm picture of the overall moisture condition of the slab.

ASTM D4263

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. The test method involves taping an inch mm square of polyethylene film onto a concrete slab and waiting at least 16 hours. Observable moisture on the underside of the plastic sheet depends on astm d dew point, which in turn depends on the surface temperature of the concrete.

Yes, it matters a great deal. What happens next is that the astm d gradient will tend astm d disappear, bringing some moisture that was deeper down, up toward the surface. Some methods of concrete moisture testing use a simple, qualitative approach.

ASTM D DOWNLOAD

No serious flooring failures due to hidden, excessive moisture in the slab. Observable moisture on the underside of the plastic sheet depends on the dew point, which in turn depends on the surface temperature of the concrete.

Nor d it indicate whether additional moisture is entering the slab from below, such as in the absence of axtm vapor retarder.

It sounds simple enough, right?