ASTM D3330 PDF

ASTM D/DM() includes six different test methods, depending on the specific conditions of the test and type, to be used for. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. This standard is issued under the fixed designation D/DM; the number 1 This test method is under the jurisdiction of ASTM Committee D10 on.

Author: Sakasa Mooguzahn
Country: Cambodia
Language: English (Spanish)
Genre: Environment
Published (Last): 17 September 2016
Pages: 332
PDF File Size: 7.95 Mb
ePub File Size: 11.42 Mb
ISBN: 659-5-22760-668-2
Downloads: 77471
Price: Free* [*Free Regsitration Required]
Uploader: Vushicage

ASTM D3330

Need help or have a question? ASTM D Test Method D gives a measure of the adherence of atm release liner to the adhesive of either single- or double-coated tape.

Remove a mm specimen of the tape to be tested. The data obtained provide a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive adhesive tape. For this test we recommend that care be taken in aligning the grips to prevent the backside of the tape specimen from rubbing.

Link to Active This link will always route to the current Active version of the standard.

ASTM D Peel Adhesion Pressure Sensitive Adhesive Tapes

GK Mechanical Vice Grip. We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications.

It is also important to align the specimen perpendicular in the grips so that the peel line is straight across. A key issue that many people encounter when testing degree peel tests to 3d330 D, is that both sides of the adhesive specimen can accidentally rub together during testing.

If this occurs, the friction of that touching will cause errors in the peel force data.

e3330 Rated to 1 kN lbf Maximum specimen thicknesses from 10 mm to 50 mm 0. A strip of tape is applied to a standard test panel that with controlled pressure from a TestResources Sample Roller.

Secure the loose end of the tape with the tab into the upper grip.

ASTM D Test Method D provides a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive adhesive tape. XLW EC Auto Tensile Tester XLW EC Auto Tensile Tester can be used to measure tensile, peeling, deformation, tearing, heat sealing, adhesive, puncture force, opening force and low speed unwrapping force as well as other performance of plastic films, composite materials, soft package materials, plastic flexible tube, adhesives, adhesive tape, label stickers, medical plasters, release paper, protection films, combined caps, aluminium foil, diaphragm, back sheets, non-woven fabrics, rubber, paper, etc.

  AINSI PARLA ZARATHUSTRA PDF

Fold over 12 mm at one end, adhesive to adhesive to form a tab. If you would rather see the data in astmm and study the peel interface at the same time, we would provide you with our XyLive Software.

MED Medical Packaging Tester is professionally applicable to the determination of force properties of various medical packaging materials, with high precision better than 0. When testing liner side adhesion, the face side adhesive is adhered to a thin polyester film.

In a liner-side application, the transfer tape is applied to a strip of 0. If the adherent is set on an angle, that will cause an error. The tape is applied to atsm substrate with an even pressure using a handheld roller.

This method is the same procedure as Method A, but measured for the thin polyester film applied to double-coated tape. Therefore, these test methods cannot be used to pinpoint the specific cause s of non-uniformity.

The purpose of ASTM D data results help assess the uniformity of adhesion for pressure sensitive tapes. Place the panel into the peel test machine grips and peel back 22 mm of the bottom half of the tape sample so that the specimen is doubled over itself at degrees. They can help you configure the best test machine and grips for your specimens.

For ASTM D, we would configure a small capacity load cell 10 or 25 pound for this low force peel test. The P consists of a vertical load frame, an electromechanical actuator, load cell, a tocuhpad test controller, XY test software and peel grips. The assessment may be within a roll of tape, between rolls, or between production lots.

Now apply a strip of the tape to a rigid panel, such as the standard stainless steel panel. The tape is peeled from the panel at 90 degree angle at a constant speed, during which time the force required to effect peel is measured. For more information on how Labthink can help your company profit through testing, please Click the button. XLW Auto Tensile Tester XLW Auto Tensile Tester is applicable to the determination of physical mechanical properties of plastic films, laminated materials, flexible packaging materials, plastic flexible tube, adhesives, adhesive tapes, pressure sensitive tapes, adhesive bandage plasterrelease paper, protective films, flip off cap, foil, diaphragm, back sheet, non-woven, rubber, and paper fiber, etc.

  ANVIZ OA200 PDF

In a face-side application, the tape is adhered to a standard steel panel or your chosen substrate in the same manner as the previous methods mention with pressure sensitive tape. Rated to N 50 lbf Maximum specimen thickness of 8 mm 0. MEGA Auto Tensile Tester MEGA Auto Tensile Tester is professionally designed for the determination of tensile strength, peel strength, tear strength, heat seal strength and adhesiveness of plastic films, composite films, flexible packaging materials, adhesives, adhesive tapes, pressure sensitive tapes, medical patches, protective films, release paper, rubber and paper, etc.

XLW M Auto Tensile Tester XLW M Auto Dd3330 Tester is designed for the test of physical mechanical properties of plastic films, laminated materials, flexible packaging materials, plastic flexible tube, adhesives, adhesive tapes, pressure sensitive tapes, and adhesive bandage plaster etc.

Pneumatic grips are useful for easily aligning your specimen to reduce any rubbing issues.

ASTM D / DM – 04() Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape

When testing face side adhesion, the double-coated tape is adhered to a stainless steel panel or your chosen substrateliner side up. Given specific pressure-sensitive tape and a requirement in d330 of the minimum or maximum peel value expected for this tape, the data from the test asttm be used in conjunction with acceptance criteria.

Ask for more details or tell us your test requirements. Apply a second strip of the tape to the backing of the first strip on the test panel, taking care to align the edges of the second specimen with those of the strip in the test panel. 3d330 Version s – view previous versions of standard. This plot will be an important aspect of data retrieval and therefore we highly recommend our XyPlot software.

The liner is removed and the tape is applied adhesive down to the substrate.